1. Home
    2. testo 176 T4

    testo 176 T4 - Temperature data logger

    0572 1764
  1. Super size memory for upto 2 million readings, upto 8 years battery life
  2. For measuring and logging the temperature at four different sites simultaneously
  3. Extremely wide measuring range of -200 °C to 1000 °C
  4. Free download of basic software to carry out data analysis on your PC
  5. The testo 176 T4 temperature data logger can measure the temperature at upto four different measurement sites simultaneously. It has a super size memory for upto 2,000,000 readings and is compatible with a number of different thermocouples making it ideal for professional use in a variety of fields.
    • not available

      Professional software with Excel export function for programming the logger and data analysis.

    • not available

      Product registration

      When you register your product, we will extend the regular manufacturer's warranty by one year.

      Register now

    With testo 176 T4 temperature data logger, you can tell at a glance if the temperature of the room or facility is within the prescribed thresholds. It can measure the temperature at upto four different sites simultaneously and has a super size memory that can save up to 2,000,000 readings. This gives you the freedom to read out the logger data at longer intervals, even when measuring cycles are shorter.

    You will need at least one temperature sensor to use your data logger. There is a wide selection of thermocouple sensors ranging from type K, T or J sensors to air, surface or probe sensors available.


    Technical features and benefits in the field

    The temperature data logger’s display provides you with a wide range of valuable information including current measurement values, threshold values, points where these thresholds have been exceeded, min/max values as well as the remaining battery power. And because all these values can be read off directly from the display, there is no need for you to boot up your PC. In addition to this nice little detail, the temperature data logger also has a super size memory and an exceptionally long battery life of up to 8 years. This gives you the freedom to read out the logger data at longer intervals, even when measuring cycles are shorter.

    The testo 176 T4 temperature data logger is IP 65 protected and can therefore also be used in dusty and dirty work environments. The standard AA batteries can be replaced by the user.


    Possible areas of application

    -  Checking the temperature in ultra-low temperature freezers or under cryogenic conditions

    -  Measuring and logging flow and return temperatures at under floor heating distributors in order to check that they are working properly

    -  Checking process temperatures

    -  Checking flow and return temperatures of heating systems



    Programming and analyzing the temperature data logger

    Choose one of three software versions to program or read out the temperature data logger or to analyze the measuring data obtained on the PC:

    Software ComSoft Basic– available for free downloading – allows you to program the temperature data logger and analyze the data quickly and easily

    Software ComSoft Professional– optional – provides you with additional possibilities and a more detailed analysis of the temperature values

    Software ComSoftCFR 21 Part11– optional – ideal for the special demands of the pharmaceutical sector in compliance with 21 CFR Part 11

    You will need a USB cable (not included) to program the temperature data logger. The data can be transferred to the PC either via USB cable or SD card. Both are available as accessories which can be ordered along with testo 176 T4.

    testo 176 T4 temperature data logger with external sensor ports (TC type T, K and J), wall mount, lock, battery, calibration certificate.

    Temperature - TC Type K (NiCr-Ni)

    Measuring range
    -200 to +1000 °C
    Accuracy
    ±0.5 % of mv (+70.1 to +1000 °C) ±1 Digit
    ±0.3 °C (-100 to +70 °C) ±1 Digit
    ±1 % of mv (-200 to -100.1 °C) ±1 Digit
    Resolution
    0.1 °C

    Temperature - TC Type T (Cu-CuNi)

    Measuring range
    -200 to +400 °C
    Accuracy
    ±0.3 °C (-100 to +70 °C) ±1 Digit
    ±1 % of mv (-200 to -100.1 °C) ±1 Digit
    ±0.5 % of mv (+70.1 to +400 °C) ±1 Digit
    Resolution
    0.1 °C

    Temperature - TC Type J (Fe-CuNi)

    Measuring range
    -100 to +750 °C
    Accuracy
    ±0.5 % of mv (+70.1 to +750 °C) ±1 Digit
    ±0.3 °C (-100 to +70 °C) ±1 Digit
    Resolution
    0.1 °C

    Air probes

    Food probes

    Surface probes

  6. Surface probes
    Spare meas. head for pipe wrap probe, TC Type K
    Spare measuring head for pipe wrap probes (TC type K) - Measuring range: -60 to +130°C
      :
      0602 0092
    • Surface probes
      Fast-reaction paddle surface probe
      Fast-reaction paddle surface probe (TC type K) - Measuring range: - 0 to +300°C
        :
        0602 0193
        Rs 18,810.00
      • Surface probes
        Fast-action surface probe with sprung thermocouple strip
        Fast-action surface probe (TC type K) – measuring range -60 to +300 °C, short-term up to +500 °C
          :
          0602 0393
          Rs 18,165.00
        • Surface probes
          Efficient, waterproof surface probe with small measurement head
          Waterproof surface temperature probe with a small measuring head (TC type K) – measuring range: -60 °C to +1000 °C
            :
            0602 0693
            Rs 16,475.00
          • Surface probes
            Fast-action surface probe with sprung thermocouple strip
            Fast-action, angled surface temperature probe (TC type K) for flat and uneven surfaces – measuring range: -60 to +300 °C
              :
              0602 0993
              Rs 21,405.00
            • Surface probes
              Waterproof surface probe with widened measurement tip
              Waterproof surface temperature probe with widened measuring tip (TC type K) for flat surfaces – measuring range -60 to +400 °C
                :
                0602 1993
                Rs 9,085.00
              • Surface probes
                Flat head surface probe with telescopic handle max. 680 mm
                Surface temperature probe (TC Type K) with telescope
                  :
                  0602 2394
                • Surface probes
                  Pipe wrap probe for pipe diameter 5 to 65 mm
                  Temperature probe (TC type K) with clamping bracket for measurements on pipes with Ø 5-65 mm – Measuring range -60 to +130°C, briefly up to +280°C
                    :
                    0602 4592
                    Rs 19,200.00
                  • Surface probes
                    Clamp probe for measurements on pipes
                    Clamp probe (TC type K) for temperature measurements on pipes with Ø 15-25 mm – Measuring range -50 to +100°C, briefly up to +130°C
                      :
                      0602 4692
                      Rs 9,990.00
                    • Surface probes
                      Magnetic probe (TC type K) - for surface temperatures
                      Surface temperature probe with magnet (TC type K), adhesive power 20 N – Measuring range -50 to +170°C
                        :
                        0602 4792
                        Rs 22,835.00
                      • Surface probes
                        Magnetfühler, Haftkraft ca. 10 N, mit Haft-Magneten
                        Surface temperature probe with magnet (TC type K), adhesive power 10 N – Measuring range -50 to +400°C
                          :
                          0602 4892
                          Rs 25,430.00
                        • Surface probes
                          Waterproof surface probe with widened measurement tip
                          Waterproof surface probe (TC type T) with wider measuring tip - measuring range: -50 to +350°C
                            :
                            0603 1993
                            Rs 9,600.00
                          • Surface probes
                            Pipe wrap probe with velcro strip
                            Temperature probe with Velcro (TC Type K)
                              :
                              0628 0020
                              Rs 6,620.00
                            • Thermocouples

                              immersion/ penetration probes

                              Checking the temperature in super freezers or under cryogenic conditions

                              Specific products must be stored under extremely cold conditions so as to ensure their quality. Therefore, in many laboratories and research facilities you can for instance find super freezers which can be cooled down to -80 °C using liquid nitrogen or dry ice.
                              In many cases storage under cryogenic conditions is even required. So, particular biological or blood products are for example stored and transported at -196 °C. Special measuring instruments, which are also fit for purpose at such low temperatures, are needed to check these extreme conditions.

                              Monitoring process temperatures

                              For production quality assurance, the temperature must frequently be checked at various points in production processes. Whether it is the air temperature, the temperature of production items themselves or the surface temperature of machines or motors.
                              Using thermocouple probes, data loggers can also record data in the kinds of extreme temperature ranges that are often to be found in production processes. The probe's fast speed of response contributes here to a good measurement result being achieved even in processes where temperatures change quickly.

                              Checking the flow and return temperature of heating systems

                              The heating period starts in autumn and with it the time for tenants to complain that the apartment cannot be heated to the extent they want as well. Using flexible external pipe wrap probes, you can for instance check the flow and return temperature of individual heaters in a targeted way, so as to identify causes and remedy them.

                              testo 176T3