1. Home
    2. testo 875-i Building diagnosis kit

    testo 875-i Building diagnosis kit - Thermal imager testo 875-2i with radio humidity probe

    0563 0875 V2 B1
  1. Building thermography: Direct display of the risk of mould via traffic light colours
  2. Very good image quality: IR resolution 160 × 120 pixels, upgrade with SuperResolution Technology to 320 × 240 pixels
  3. Including radio humidity probe and licence-free testo IRSoft professional software
  4. Including a built-in digital camera and voice recording via a headset
  5. Product no longer available. Are you familiar with the alternative?
    Why not enjoy the benefits that it has to offer: >> To the product
    We developed the testo 875-2i infrared camera with built-in digital camera to make your work in industrial and building thermography even easier, quicker and more efficient!
    You can carry out completely non-destructive tests on materials and components in industrial thermography with the testo 875-2i. The high temperature option extends the measuring range from +350 °C to +550 °C. Using the built-in digital camera, you can create a real image in parallel to the thermal image. So as to make the documentation and assignment of real and thermal images even easier for you, the testo 875-2i infrared camera is also equipped with voice recording. This means you can save comments to go with your images using the headset.
    In building thermography you can efficiently detect possible structural defects and places with a risk of mould with the testo 875-2i infrared camera. Traffic light colours in the display (red, yellow and green) directly indicate to you critical places with a risk of mould.

    The testo 875-2i infrared camera’s technical features

    The testo 875-2i infrared camera is not only characterised by its intuitive operation. It also simplifies professional industrial and building thermography and has the following impressive features:
    • Built-in digital camera with power LEDs: Recording real images in parallel to each infrared image makes documentation and assignment easier. The built-in power LEDs guarantee optimum illumination of dark areas
    • Voice recording included: You can save comments to go with your images using the headset
    • Resolution and image quality: Detector size 160 × 120 pixels = 19 200 temperature measuring points. SuperResolution Technology enables you to take image quality right up to the next level of 320 × 240 pixels in next to no time. Four times as many readings and a geometric resolution that has been improved by a factor of 1.6 mean you get even more detail and even greater reliability with thermographic measurements
    • Thermal sensitivity < 50 mK: Thanks to a temperature resolution of < 50 mK, even the smallest temperature differences can be seen
    • High-quality 32° × 23° lens: The lens with its manual focusing enables a wide field of view and an ideal overview of the temperature distribution, along with precise focusing on the object being measured
    • 9° × 7° telephoto lens: Record very distant objects precisely with the exchangeable 9° × 7° telephoto lens (optional)
    • Automatic hot/cold spot detection: Critical temperature conditions are directly displayed during thermography
    • Special measuring mode for detecting areas with a risk of mould for building thermography: The dew point in the room is calculated by manual entry of the ambient temperature and humidity. The surface temperature value measured by the infrared camera is then compared to the dew point. The display now shows the risk of mould in traffic light colours (red, yellow and green). It is easier with the radio humidity probe: Automatic transmission of readings means that manual input of humidity and ambient temperature is no longer needed
    • Solar mode: The solar radiation value can be input into the infrared camera and stored with each infrared image
    • Pro software for image evaluation on the PC included. You can also choose to save the infrared images as JPEGs. Find out more about the software
    • Standard measuring range from -30 to +350 °C. The high temperature option enables flexible extension of the measuring range for industrial thermography up to +550 °C

    The testo 875-2i infrared camera with SuperResolution and digital camera is supplied together with the following accessories:
    • Wireless humidity probe
    • Robust case
    • Pro software IRSoft (free download)
    • Soft case
    •  Carrying strap for the infrared camera
    • SD memory card
    •  USB cable for data transfer to PC
    • Lens cleaning cloth
    • Mains unit
    • Li-ion battery
    • Adapter for tripod mounting
    • Headset for voice recording

    In the event of retrofitting, please contact our customer service for the following options:
    • 9° × 7° telephoto lens (order code: A1)

    Ambient Condition

    Storage temperature
    -30 °C
    -30 to +60 °C
    Operating temperature
    -15 °C
    -15 to +40 °C
    Air humidity
    20 to 80 %RH non-condensing
    Housing protection class
    IP54
    Vibration
    2G

    Image output visual

    Image size
    640 x 480 pixels
    Minimum focus distance
    0.4 m

    Image presentation

    Display type
    3.5" LCD with 320 x 240 pixels
    Display option
    IR image only; real image only; IR image / real image
    Number of colours
    10
    Colours
    10 (iron, rainbow, rainbow HC, cold-hot, blue-red, grey, inverted grey, sepia, Testo, iron HT)
    Video output
    USB 2.0

    Detecting structural defects and ensuring construction quality

    • Detect potential building defects, prove quality and the implementation of construction measures without contact – with the help of thermal images
    • Test air-tightness of windows and doors
    • Locate insulation errors and cold bridges in a building shell
    • Detect and visualize mould-risk areas
    testo 8xx application

    Professional energy consultation

    • Analyze building shells, evaluate energy efficiency, identify energy-saving potential with a thermal imager from Testo
    • Easy recording and documentation of energy loss from buildings
    • Prove faulty insulation and cold bridges without contact, and visualize them in an infrared image
    • Localize untight spots in new buildings quickly and easily in combination with Blower Door
    testo 8xx application

    Preventing mould formation

    • Localize mould-risk areas quickly and easily: These areas are presented in red in the imager display when the imager is in humidity mode
    testo 8xx application

    Easy checking of heating systems and installations

    • test heating and air conditioning/ventilation systems: Use a thermal imager to identify irregularities in the temperature distribution quickly and easily
    • Localization of the course of heating loops in underfloor heating systems
    • Testo radiators for silting
    • Measure flow and return temperatures
    testo 8xx application

    Localize pipe ruptures

    • Reliably determine pipe ruptures with the help of a thermal imager – without unnecessarily opening walls and floors
    • Precise localization of leakages in underfloor heating and other inaccessible pipe systems
    testo 8xx application

    Locating leaks in flat roofs

    • Detection of damp in roofs: Based on temperature differences (such as occur mainly in flat roofs), thermal imagers show areas on the roof with sealed-in moisture or damaged insulation
    testo 8xx application