  1. Practical for frequent and long-term measurements: memory capacity of 1 million readings, up to 3 years’ battery life
  2. Very large temperature measuring range from -50 °C to +1 000 °C
  3. Including wall bracket
  4. Measurement data analysis and documentation: three different software versions to choose from, basic software available as a free download
  5. The testo 175 T3 temperature logger with its two connections for external thermocouple probes is a good idea when you would like to record your temperatures at two locations in parallel: for example when measuring the flow and return temperature on radiators. The readings are securely saved in the temperature logger and are available for later measurement data analysis and documentation.
    • not available

      Professional software with Excel export function for programming the logger and data analysis.

    The testo 175 T3 temperature logger is equipped with two connections for external thermocouple probes (type T or type K). This means the data logger is ideally suited for carrying out temperature recording on two channels. This is for instance necessary, if you want to check that a heating system is working properly. To do this, the temperature logger measures the flow and return temperature simultaneously. The data logger can likewise be used in industrial production control, if process temperatures need to be checked at different locations.

    State-of-the-art measuring technology, high level of data security

    You can select the external thermocouple probes from our wide range of probes and order them to go with the data logger. This gives you flexibility and means you can decide yourself exactly what your temperature logger has to be capable of doing. The range we offer includes surface probes, air probes and immersion/penetration probes. The measuring range and accuracy depend on the thermocouple probes selected. In principle, it is possible to measure from -50 °C to +1 000 °C with an appropriate probe.

    You can display the current measuring values, min./max. values, set limit values, violations of limit values and remaining battery life on the clear display. This means you have the opportunity to read important values at any time and do not need to resort to a read-out of the temperature logger on the PC straight away every time you want to do a quick data check.

    The long battery life of up to 3 years and the large measurement data memory which records up to 1 million readings are particularly convenient for users: because only relatively infrequent reading of the temperature logger is needed, even with shorter measurement intervals. You can use standard batteries (AAA) to run the data logger and you can replace them yourself. Particularly practical when temperatures are to be recorded in a polluted and dust-laden environment: The temperature logger has protection against dust ingress as well as water spray and jets according to protection class IP 65.

    Good to know: Saved measurement data will not be lost even when the battery is empty or being replaced. You can therefore rely on a high level of data security when using the temperature logger.

    Programming and analysis with the temperature logger

    You can choose between three different software versions for programming and reading the data logger along with measurement data analysis on the PC:

    • ComSoft Basic software – can be downloaded free of charge – for fast programming of the data logger and easy measurement data analysis
    • ComSoft Professional software – can be ordered as an option – offers various possibilities for more detailed analysis of the temperature readings
    • ComSoft CFR 21 Part 11 software – can be ordered as an option – suitable for special requirements according to CFR 21 Part 11 in the pharmaceutical sector

    testo 175 T3 temperature logger, 2-channel temperature logger with external sensor connections (thermocouple type T and type K), including wall bracket, lock, batteries and calibration protocol. Caution: At least one external thermocouple probe (optional) must be connected to commission the temperature logger. In addition, you also need a USB cable (optional) in order to programme and read out your data logger. You can order both the probe and USB cable to go with your temperature logger. You can also transfer the measurement data to your PC using the USB cable (or with an SD card which is also available as an option).

    Temperature - TC Type K (NiCr-Ni)

    Measuring range
    -50 to +1000 °C
    Accuracy
    ±0.7 % of mv (+70.1 to +1000 °C) ±1 Digit
    ±0.5 °C (-50 to +70 °C) ±1 Digit
    Resolution
    0.1 °C

    Temperature - TC Type T (Cu-CuNi)

    Measuring range
    -50 to +400 °C
    Accuracy
    ±0.5 °C (-50 to +70 °C) ±1 Digit
    ±0.7 % of mv (70.1 to +400 °C) ±1 Digit
    Resolution
    0.1 °C

    General technical data

    Weight
    130 g
    Dimensions
    96 x 54 x 29 mm
    Operating temperature
    -20 to +55 °C
    Protection class
    IP65
    Channels
    2 external
    Product-/housing material
    Plastic
    Product colour
    Black
    Standards
    EU-guideline 2014/30/EU; 2011/65/EU
    Measuring rate
    10 s - 24 h
    Battery type
    3 x AIMn type AAA or Energizer
    Battery life
    3 years at 15 min. meas. rate, +25 °C
    Memory
    1,000,000 measuring values
    Storage temperature
    -20 to +55 °C

    Air probes

    Food probes

    Surface probes

  6. Surface probes
    Spare meas. head for pipe wrap probe, TC Type K
    Spare measuring head for pipe wrap probes (TC type K) - Measuring range: -60 to +130°C
      :
      0602 0092
    • Surface probes
      Fast-reaction paddle surface probe
      Fast-reaction paddle surface probe (TC type K) - Measuring range: - 0 to +300°C
        :
        0602 0193
      • Surface probes
        Fast-action surface probe with sprung thermocouple strip
        Fast-action surface probe (TC type K) – measuring range -60 to +300 °C, short-term up to +500 °C
          :
          0602 0393
        • Surface probes
          Efficient, waterproof surface probe with small measurement head
          Efficient, waterproof surface probe with small measurement head for flat surfaces, T/C Type K
            :
            0602 0693
          • Surface probes
            Fast-action surface probe with sprung thermocouple strip
            Fast-action, angled surface temperature probe (TC type K) for flat and uneven surfaces – measuring range: -60 to +300 °C
              :
              0602 0993
            • Surface probes
              Waterproof surface probe with widened measurement tip
              Waterproof surface temperature probe with widened measuring tip (TC type K) for flat surfaces – measuring range -60 to +400 °C
                :
                0602 1993
              • Surface probes
                Pipe wrap probe for pipe diameter 5 to 65 mm
                Temperature probe (TC type K) with clamping bracket for measurements on pipes with Ø 5-65 mm – Measuring range -60 to +130°C, briefly up to +280°C
                  :
                  0602 4592
                • Surface probes
                  Clamp probe for measurements on pipes
                  Clamp probe (TC type K) for temperature measurements on pipes with Ø 15-25 mm – Measuring range -50 to +100°C, briefly up to +130°C
                    :
                    0602 4692
                  • Surface probes
                    Magnetic probe (TC type K) - for surface temperatures
                    Surface temperature probe with magnet (TC type K), adhesive power 20 N – Measuring range -50 to +170°C
                      :
                      0602 4792
                    • Surface probes
                      Magnetfühler, Haftkraft ca. 10 N, mit Haft-Magneten
                      Surface temperature probe with magnet (TC type K), adhesive power 10 N – Measuring range -50 to +400°C
                        :
                        0602 4892
                      • Surface probes
                        Waterproof surface probe with widened measurement tip
                        Waterproof surface probe (TC type T) with wider measuring tip - measuring range: -50 to +350°C
                          :
                          0603 1993
                        • Surface probes
                          Pipe wrap probe with velcro strip
                          Temperature probe with Velcro (TC Type K)
                            :
                            0628 0020
                          • Thermocouples

                            immersion/ penetration probes

                            Monitoring the flow and return temperature of heating systems

                            The heating period begins in autumn and with it complaints from tenants that their apartments cannot be heated to the extent they would like. The flow and return temperature of individual radiators, for example, can be specifically monitored with the aid of flexible external pipe wrap probes, which enable causes to be identified and remedied.

                            testo 175T3

                            Monitoring process temperatures

                            In production processes, the temperature often has to be checked in different places to ensure production quality: whether this is the air temperature, the temperature of manufactured products themselves, or the surface temperature of machines or engines and motors.
                            With the aid of thermocouple probes, data loggers can also record in the extreme temperature ranges prevalent in production processes. The extremely fast response of the probes means that even in processes with fast changing temperatures a good measurement result can be achieved.