  1. Extremely wide measuring range from -200 °C – 1 000 °C
  2. Super size memory for up to 2 million readings, up to 8 years battery life
  3. For measuring and logging the temperature at four different sites simultaneously
  4. Carry out data analysis on your PC: three software options to choose from; Basic software as free download
  5. The testo 176 T4 data logger can measure the temperature at up to four different measurement sites simultaneously. It also has a super size memory for up to 2 000 000 readings, an exceptionally wide measurement range and is compatible with a number of different thermocouple elements making it ideal for professional use in a variety of different fields.
    • not available

      Professional software with Excel export function for programming the logger and data analysis.

    The testo 176 T4 temperature data logger can tell you at a glance if the temperature of the room or facility is within the prescribed thresholds. It can measure the temperature at up to four different sites simultaneously and has a super size memory that can save up to 2 000 000 readings. This gives you the freedom to read out the logger data at longer intervals, even when measuring cycles are shorter.

    You will need at least one temperature sensor to use your logger. There is a wide selection of thermocouple sensors ranging from type K, T or J sensors to air, surface or probe sensors available.

    Technical features and benefits in the field

    The logger’s display provides you with a wide range of valuable information including current measurement values, threshold values, points where these thresholds have been exceeded, min/max values as well as the remaining battery power. And because all these values can be read off directly from the display, there is no need for you to boot up your PC. In addition to this nice little detail, the logger also has a super size memory and an exceptionally long battery life of up to 8 years. This gives you the freedom to read out the logger data at longer intervals, even when measuring cycles are shorter.

    The  testo 176 T4 data logger is IP 65 protected and can therefore also be used in dusty and dirty work environments. The standard AA batteries can be replaced by the user.

    Possible areas of application

    • Checking the temperature in ultra-low temperature freezers or under cryo conditions
    • Measuring and logging flow and return temperatures at underfloor heating distributors in order to check that they are working properly
    • Checking process temperatures
    • Checking flow and return temperatures of heating systems

    Programming and analyzing your data logger

    Choose one of three software versions to program or read out your logger or to analyze the measuring data you have obtained on your PC:
     

    • Software ComSoft Basic – available for free downloading – allows you to program your logger and analyze the data quickly and easily
    • Software ComSoft Professional – optional – provides you with additional possibilities and a more detailed analysis of the temperature values
    • Software ComSoft CFR 21 Part 11 – optional – ideal for the special demands of the pharmaceutical sector in compliance with 21 CFR Part 11

    You will need a USB cable (not included) to program your data logger. The data can be transferred to your PC either via USB cable or SD card. Both are available as accessories which can be ordered together with your testo 176 T4.

    testo 176 T4 temperature data logger with external sensor ports (TC type T, K and J), wall mount, lock, battery, calibration protocol.

    Temperature - TC Type K (NiCr-Ni)

    Measuring range
    -200 to +1000 °C
    Accuracy
    ±0,3 °C (-100 to +70 °C) ±1 Digit
    ±1 % of mv (-200 to -100,1 °C) ±1 Digit
    ±0,5 % of mv (+70,1 to +1000 °C) ±1 Digit
    Resolution
    0,1 °C

    Temperature - TC Type T (Cu-CuNi)

    Measuring range
    -200 to +400 °C
    Accuracy
    ±0,3 °C (-100 to +70 °C) ±1 Digit
    ±0,5 % of mv (+70,1 to +400 °C) ±1 Digit
    ±1 % of mv (-200 to -100,1 °C) ±1 Digit
    Resolution
    0,1 °C

    Temperature - TC Type J (Fe-CuNi)

    Measuring range
    -100 to +750 °C
    Accuracy
    ±0,3 °C (-100 to +70 °C) ±1 Digit
    ±0,5 % of mv (+70,1 to +750 °C) ±1 Digit
    Resolution
    0,1 °C

    Accessories

  6. Accessories
    Connection cable
    USB connection cable, instrument-PC
      :
      0449 0047
      € 27,00 € 33,75
    • Checking the temperature in super freezers or under cryogenic conditions

      Specific products must be stored under extremely cold conditions so as to ensure their quality. Therefore, in many laboratories and research facilities you can for instance find super freezers which can be cooled down to -80 °C using liquid nitrogen or dry ice.
      In many cases storage under cryogenic conditions is even required. So, particular biological or blood products are for example stored and transported at -196 °C. Special measuring instruments, which are also fit for purpose at such low temperatures, are needed to check these extreme conditions.

      Monitoring process temperatures

      For production quality assurance, the temperature must frequently be checked at various points in production processes. Whether it is the air temperature, the temperature of production items themselves or the surface temperature of machines or motors.
      Using thermocouple probes, data loggers can also record data in the kinds of extreme temperature ranges that are often to be found in production processes. The probe's fast speed of response contributes here to a good measurement result being achieved even in processes where temperatures change quickly.

      Checking the flow and return temperature of heating systems

      The heating period starts in autumn and with it the time for tenants to complain that the apartment cannot be heated to the extent they want as well. Using flexible external pipe wrap probes, you can for instance check the flow and return temperature of individual heaters in a targeted way, so as to identify causes and remedy them.