Registracija proizvoda
Prijavljivanjem Vašeg proizvoda produljujemo regularno jamstvo proizvođača za dodatnih godinu dana.
Measuring range | −40 to +1200 °C |
---|---|
Accuracy | ±0,5 % of mv (Remaining Range) ±0,5 °C (0,0 to +100,0 °C) |
Resolution | 0,1 °C (−40 to +999,9 °C) 1 °C (Remaining Range) |
Measuring range | −100 to +200 hPa |
---|---|
Accuracy | ±1,5 % of mv (+100,1 to +200 hPa) ±0,5 hPa (0 to +50,0 hPa) ±1 % of mv (+50,1 to +100,0 hPa) |
Resolution | 0,01 hPa |
Measuring range | 0 to 21 Vol.% |
---|---|
Accuracy | ±0,2 Vol.% |
Resolution | 0,1 Vol.% |
Measuring range | −9,99 to +40 hPa |
---|---|
Accuracy | ±1,5 % of mv (3,01 to +40 hPa) ±0,02 hPa (+0,1 to +3,00 hPa) ±0,005 hPa (+0 to +0,1 hPa) |
Resolution | 0,001 hPa (0 to 0,1 hPa) 0,01 hPa (Remaining Range) |
Measuring range | 0 to 120 % |
---|---|
Resolution | 0,1 % |
Measuring range | 0 to 99,9 % |
---|---|
Resolution | 0,1 % |
Measuring range | Display range 0 to CO₂ max |
---|---|
Accuracy | ±0,2 Vol.% |
Resolution | 0,1 Vol.% |
Measuring range | 0 to 4000 ppm |
---|---|
Accuracy | ±5 % of mv (401 to 2000 ppm) ±10 % of mv (2001 to 4000 ppm) ±20 ppm (0 to 400 ppm) |
Resolution | 1 ppm |
Measuring range | 0 to 2000 ppm |
---|---|
Accuracy | ±10 % of mv (101 to 2000 ppm) ±10 ppm (0 to 100 ppm) |
Resolution | 1 ppm |
Operating humidity | 15 to 90 %RH non-condensing |
---|---|
Weight | approximately 800 g |
Dimensions | 244 (including probe connection) x 98 x 59 mm (LxWxH) |
Operating temperature | −5 to +45 °C |
Protection class | IP40 |
Product colour | black/orange |
Display type | 5.0" touch display, HD 1280*720 pixels, IPS (160 k) |
Power supply | Rechargeable battery, USB mains unit |
Warranty conditions | https://www.testo.com/guarantee |
Authorizations | TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3 |
Guarantee | Gas sensors (O₂, CO) 24 months; rechargeable battery: 12 months; Thermocouple 12 months |
Memory | 1.000.000 measuring values |
Battery life | 10 h |
Storage battery type | Lithium ion battery |
Storage temperature | −20 to +50 °C |
Charging temperature | 0 to +45 °C |
Measuring Range | -50 to +50 Pa |
---|---|
Accuracy | ±3 % of mv (Remaining Range) ±0,3 Pa (< 10 Pa) |
Resolution | 0,1 Pa |
Diameter probe shaft | 6 mm |
---|---|
Cable length | 1,5 m |
Length probe shaft | 180 mm |
Product colour | Black |
Temperature maximum | 500 °C |
Diameter | 6 mm |
Weight | 346 g |
System requirements | Windows® 7; Windows® 8; Windows® 10 |
---|---|
Weight | 1400 g |
---|---|
Dimensions | 256 x 516 x 135 mm ((LxWxH)) |
Product colour | Black |
Battery life | None, operated via testo 300 |
---|---|
Connection | TUC 1 or TUC 2 |
Radio range | 100 m |
compatible with | testo 510i, testo 115i, testo 915i |