1. Home
    2. testo 885 kit

    testo 885 kit - Thermal imager (320 x 240 pixels, focus manual/auto, laser, 2 lenses selectable)

    0563 0885 X2
  1. testo 885 professional thermal imager: resolution 320 x 240 pixels, upgradable to 640 x 480 pixels with SuperResolution, thermal sensitivity < 30 mK
  2. Choice of lenses between 30° x 24° standard lens, 25° x 19° lens and 11° x 9° telephoto lens – you are free to choose two lenses
  3. Assistance functions for efficient measurement: SiteRecognition, panoramic image, process analysis package with sequence capturing and radiometric video (latter optional)
  4. Also included in the kit: licence-free testo IRSoft professional software, lens protection glass, spare rechargeable battery and fast charging station
  5. Product no longer available. Are you familiar with the alternative?
    Why not enjoy the benefits that it has to offer: >> To the product
    Professional thermography with all your practical needs: the testo 885 thermal imager for building and industrial thermography meets the highest requirements all on its own. The kit allows you to choose a total of two lenses from three that are available (standard, 25° or telephoto lens). So cover yourself for all practical applications!
    Carry out detailed energy consultations, analyze building shells completely at a glance and check solar plants when installing, maintaining or repairing them. Check electrical systems, precisely visualize critical temperatures on circuit boards and perform measurements accurately, even at high temperatures up to 1,200°C.

     


    More impressive details about the testo 885 kit with two lenses

    testo 885 thermal imager:
    • Detector size 320 x 240 pixels = 76,800 temperature measuring points, with SuperResolution Technology able to boost image quality to 640 x 480 pixels
    • Process analysis package (optional): the combination of fully radiometric video and sequence capturing in the camera enables wireless measurement and easier handling at the measuring location
    • Thermal sensitivity < 30 mK = so that even the smallest temperature differences can be seen
    • You can also choose to save thermal images as JPEGs
    • Lots of camera angles are feasible without any problem: thanks to the ergonomic rotating handle and the rotatable, fold-out display
    • Panorama image assistant: straightforward recording and evaluation of the entire outer shells of buildings rather than the tedious evaluation of individual images
    • SiteRecognition technology: immediate identification of similar measurement objects and automatic assignment or archiving of the thermal images
    • Optional high-temperature measurement up to 1,200°C: with the high-temperature option, the measuring range can be flexibly extended up to 1,200°C
    • Special measuring mode for detecting areas susceptible to mould: the dewpoint in the room is calculated by manually entering the ambient temperature and humidity. The dewpoint is then compared with the surface temperature value measured by the camera. Traffic light colours (red, yellow, green) on the display indicate the risk of mould. The optional radio humidity probe makes things easier: automatic transmission of readings means that manual input of humidity and ambient temperature is no longer needed
    • FeverDetection (optional): use the assistant to check people for high body temperature in public places and in means of transport – for public health protection
    • Lens exchange possible
    • Voice recording possible with headset
    • Integrated digital camera with power LEDs: take real images to go with every thermal image – well-lit thanks to power LEDs. This makes assignment of the thermographic images significantly easier
    • Auto-focus for one-handed operation and to prevent blurred images
    • Minimum focus distance 10 cm

    Lenses
    You are free to choose two of a total of three lenses in this kit:

    30° x 23° standard lens (optionally included in the kit as a first or second lens):
    • Ideal for inspecting closer measurement objects
    • Large field of view
    25° x 19° lens (optionally included in the kit as a first or second lens):
    • Ideal for use in applications involving preventive maintenance
    11° x 9° telephoto lens (optionally included in the kit as a first or second lens):
    • Makes it possible to take outstanding images of measurement objects at medium and longer distances

    • testo 885 thermal imager with SuperResolution
    • 2 x lenses (choice between 30° standard lens, 25° lens or 11° telephoto lens)
    • Transport case
    • Pro software IRSoft (free download)
    • SD memory card
    • USB cable for data transfer to the PC
    • Carrying strap for the thermal imager
    • Lens cleaning cloth
    • Mains unit
    • Li-ion rechargeable battery
    • Headset for voice recording
    • Lens case
    • Lens protection glass
    • Spare rechargeable battery
    • Fast charging station

    Standards

    EU-/EG-guidelines
    2004/108/EG

    Infrared image output

    Field of view
    30° x 23° (Standard lens), 25° x 19° (25° lens), 11° x 9° (Telephoto)
    Focus
    auto / manual
    Minimum focus distance
    0.1 m (Standard lens), 0.2 m (25° lens), 0.5 m (Telephoto lens)
    Geometric resolution (IFOV)
    1.7 mrad (Standard lens), 1.36 mrad (25° lens), 0.6 mrad (Telephoto lens)
    Image refresh rate
    33 Hz
    Infrared resolution
    320 x 240 pixels
    SuperResolution (IFOV)
    1.06 mrad (Standard lens), 0.85 mrad (25° lens), 0.38 mrad (Telephoto lens)
    SuperResolution (Pixel)
    640 x 480 pixels
    Thermal sensitivity
    ˂ 30 mK at +30 °C
    Spectral range
    7,5 to 14 µm
    *inside the EU, outside 9 Hz

    Image output visual

    Minimum focus distance
    0.5 m
    Image size
    3.1 MP

    Checking as part of electrical maintenance

    In electrical installations or cables, increased temperatures are always an indication of an overload, an imminent malfunction or an existing defect. Testo thermal imagers facilitate evaluation of the heat status of low, medium and high-voltage systems. Thermographic images lead to the early detection of defective components or connections, so that the necessary preventive measures can be introduced in a targeted way. Thermography therefore minimizes dangerous fire risks and prevents costly production downtimes.
    Typical applications for the thermal imager:
    • Checking switch cabinets
    • Checking electrical connections
    • Monitoring and checking photovoltaic systems
    • Checking as part of mechanical maintenance
    0563-0890-ir-application-testo-890-electrical-maintenance.png

    Analysing building shells at a glance

    The task of taking thermal images of large buildings poses several challenges for users. Spatial restrictions due to walls, roads or safety zones around neighbouring buildings can make it impossible to capture the measuring object in a single image. In such cases, Testo thermal imagers help users obtain the necessary overview. The panorama image assistant can be used to combine several images of the building shell taken at close range into a single thermal image. Users can therefore identify thermal irregularities at a glance across the entire building shell with a high degree of detail.

    testo 885

    Providing comprehensive energy advice

    In building thermography, infrared technology is particularly suitable for quick and effective analysis of energy losses in buildings’ heating or air conditioning systems. Thanks to their high temperature resolution, Testo thermal imagers provide detailed images of inadequate insulation and thermal bridges. They are ideal for the recording and documentation of energy losses on outer windows and doors, roller blind casings, radiator niches, in roof structures or the entire building shell. Testo thermal imagers are the perfect measuring tool for comprehensive diagnosis and maintenance uses, and whenever providing energy consultation services.

    0560-0882-ir-application-testo-882-energy-advice.png

    Making it possible to see critical temperatures on circuit boards precisely

    In the field of research and development, thermal imagers are also used for the targeted analysis of temperature distribution, e. g. on circuit boards. Electronic components on circuit boards are getting smaller and smaller – thus increasing the challenges with regard to heat dissipation. Only premium-quality thermal imagers with a really fine geometric resolution are suitable for this task. Analysis of the heating and cooling behaviour over time is also helpful for optimisation and this can be carried out using the Testo thermal imager's video measurement

    testo 885

    Monitoring and checking solar energy systems

    There are two main reasons for inspecting solar energy systems: safety and performance monitoring. Solar energy systems achieve their top performance in full sunshine. Testo thermal imagers can be used to monitor photovoltaic systems of all sizes in a way that is wide-ranging, contact-free and exceptionally efficient. Malfunctions are detected, the proper functioning of all components is ensured and the greatest possible efficiency is thus achieved. Additional reliability is also achieved through the ability to enter the key measurement parameter of solar radiation intensity: the value entered is stored with the thermal image and is then available for the image analysis.

    testo 876

    Reliable high temperature measurement

    Testo thermal imagers adapt to the requirements for applications with high scene temperatures. With the high temperature option, the measuring range can be flexibly extended up to 550 °C . The high-contrast presentation on the display is achieved via the high-temperature iron HT colour palette or the special histogram adjustment.

    testo 882

    Jednostavna provjera sustava grijanja i instalacija

    • testirajte sustave grijanja i klimatizacije/ventilacije: Upotrijebite termalnu kameru za brzo i jednostavno prepoznavanje nepravilnosti u raspodjeli temperature
    • Lokalizacija toka grijaćih petlji u sustavima podnog grijanja
    • Testo radijatori za muljenje
    • Izmjerite temperature polaza i povrata
    testo 8xx application

    Utvrđivanje puknuća cijevi

    • Pouzdano odredite puknuća cijevi uz pomoć termo kamere – bez nepotrebnog otvaranja zidova i podova
    • Precizno lokaliziranje curenja u sustavima podnog grijanja i drugim nedostupnim sustavima cijevi
    testo 8xx application

    Lociranje curenja na ravnim krovovima

    • Detekcija vlage na krovovima: Na temelju temperaturnih razlika (kakve se uglavnom javljaju na ravnim krovovima), termo kamere prikazuju područja na krovu s vlagom ili oštećenom izolacijom
    testo 8xx application