  1. Hkratno, posamezno merjenje in prikaz vseh relevantnih merilnih parametrov (O2, CO, CO2, dimni plini in okoljska temperatura, CO v okolju, vleka in tlak). Prikaz lahko prilagodite prek aplikacije testo Smart App
  2. Hkratna dodatna merjenja preko aplikacije testo Smart App (na primer tlak pretoka plina, temperatura dovoda in vračanja)
  3. Enostavno in intuitivno vodenje menija
  4. Digitalna dokumentacija, prenos podatkov in upravljanje s podatki strank prek aplikacije testo Smart App
  5. Monterji in tehniki ogrevanja, ki izvajajo zagon in vzdrževanje sistemov za ogrevanje sanitarne vode in stanovanjskih prostorov, potrebujejo zanesljiv in stabilen merilni instrument, s katerim lahko enostavno opravijo svoje merilne naloge, kot je analiza izpušnih plinov. Novi testo 310 II zagotavlja individualno podporo pri njihovih vsakodnevnih merilnih nalogah in olajša njihovo delo iz dneva v dan.
    • not available

      Registracija izdelka

      Z registracijo svojega izdelka vam podaljšamo običajno garancijo proizvajalca za leto dni.

      Registrirajte izdelek zdaj

    Testo 310 II ima dve merilni celici za O2 in CO ter temperaturni senzor, vgrajen v sondo za dimne pline. Plinski senzorji merijo natančno vsebnost kisika in ogljikovega monoksida ter temperaturo dimnih plinov in okolice. Iz teh podatkov se izračunajo vsi pomembni merilni parametri, kot so vrednost CO2, stopnja učinkovitosti in izgube dimnih plinov. Poleg tega ima merilni instrument svoje prednosti v natančnosti merjenja, konfigurabilnem prikazu meritev, možnosti vzporednih meritev, intuitivnem delovanju, trpežnem ohišju in možnosti povezave z aplikacijo testo Smart App: Naš analizator dimnih plinov testo 310 II ponuja vse, kar potrebujejo moterji in tehniki za praktično delo na ogrevalnih sistemih.
     
     

    Zanesljivo testiranje ogrevalnih sistemov z analizatorjem dimnih plinov testo 310 II za začetnike

    Kompaktni analizator dimnih plinov ponuja, poleg preprostega uporabniškega vmesnika, tudi menijsko navigacijo z štirimi integriranimi merilnimi meniji za dimne pline, vlek zraka, okoljski CO in tlak. Vsi merilni rezultati so na zaslonu vidni na prvi pogled in jih je mogoče individualno nastaviti, zahvaljujoč visokoresolucijskemu grafičnemu zaslonu.

    Po potrebi lahko med merjenjem obdržite proste roke - saj lahko analizator dimnih plinov testo 310 II pritrdite na kovinske površine, na primer na gorilnik, s pomočjo magnetov na zadnji strani instrumenta. Vendar to ni edina praktična funkcionalnost: Testo Smart aplikacija vam omogoča upravljanje in konfiguriranje instrumenta preko funkcije daljinskega upravljanja.

    Robustna zasnova za zahtevna in umazana okolja, hitro kalibriranje senzorja v 30 sekundah, enostavno zamenljiv filter na sondo in hitro praznjenje kondenzacijske pasti omogočajo, da je analizator dimnih plinov odlično orodje za mehanike naprav, saj je pametno oblikovan.

    Po potrebi se merilni rezultati lahko prenesejo na dodatno dostopen Testo hitri tiskalnik prek vmesnika Bluetooth® ali pa se pošljejo po elektronski pošti in natisnejo neposredno na kraju samem.

    Analizator dimnih plinov testo 310 II vključuje tiskalnik, kalibracijski protokol za merjenje O2, CO, hPa in °C, sondo dolžine 180 mm s konusom, silikonsko cev za merjenje tlaka, termalni papir, 5 kosov delčnih filtrov in kovček.

    Sets

    Accessories

  6. Accessories
    Spare particle filter
    Spare particle filter, compact probe; 10 off
      :
      0554 0040
      € 29,00 € 35,38
    • Accessories
      Spare thermal paper
      Spare thermal paper for printer, permanent
        :
        0554 0568
        € 28,00 € 34,16
      • Accessories
        USB mains unit incl. cable
          :
          0554 1105
          € 43,00 € 52,46
        • Printer and accessories

          Draught measurement in the flue gas duct

          Draught measurement is actually a differential pressure measurement. This differential pressure occurs between two sub-areas as a result of a difference in temperature. This is turn generates a flow to compensate. In the case of flue gas systems, the difference in pressure is an indicator of the “chimney flue draught”. This is measured between the flue gas and ambient air at the measurement orifice at the core of the flue gas flow.

          To ensure the flue gases are safely transported through the chimney there must be a differential pressure (chimney flue draught) for boiler systems that work with low pressure.

          If the draught is permanently too high, the average flue gas temperature increases and therefore flue gas loss. The level of efficiency drops.

          If the draught is permanently too low, oxygen may be lacking during combustion, resulting in soot and carbon monoxide. This will also cause a drop in the level of efficiency.

          Ambient CO measurement in the heated environment

          Carbon monoxide (CO) is a colourless, odourless and taste-free gas, but also poisonous. It is produced during the incomplete combustion of substances containing carbon (oil, gas, and solid fuels, etc.). If CO manages to get into the bloodstream through the lungs, it combines with haemoglobin thus preventing oxygen from being transported in the blood; this in turn will result in death through suffocation. This is why it is necessary to regularly check CO emissions at the combustion points of heating systems, and places often frequented by people (in our case, where the combustion systems for hot water generation are), and in the surrounding areas.

          Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)

          The flue gas measurement for a heating system helps to establish the pollutants released with the flue gas (e.g. carbon monoxide CO) and the heating energy lost with the warm flue gas. In some countries, flue gas measurement is a legal requirement. It primarily has two objectives:

          1. Ensuring the atmosphere is contaminated as little as possible by pollutants; and

          2. energy is used as efficiently as possible.

          Stipulated pollutant quantities per flue gas volume and energy losses must never be exceeded.

          Measurement in terms of results required by law takes place during standard operation (every performance primarily using the appliance). Using a Lambda probe (single hole or multi-hole probe), the measurement is taken at the centre of flow in the connecting pipe (in the centre of the pipe cross-section, not at the edge) between the boiler and chimney/flue. The measured values are recorded by the flue gas analyzer and can be logged either for print out or transfer to a PC at a later stage.

          Measurement is taken by the installer at commissioning, and if necessary four weeks later by the flue gas inspector/chimney sweep, and then at regular intervals by the authorised service engineer.

          Measuring pressure on burners (nozzle pressure, gas flow pressure, etc.)

          Standard readings taken during services of domestic heating systems include checking the gas pressure on the burners. This involves measuring the gas flow pressure and gas resting pressure. The flow pressure, also called supplied pressure, refers to the gas pressure of the flowing gas and resting pressure of the static gas. If the flow pressure for gas boilers is slightly outside the 18 to 25 mbar range, adjustments must not be made and the boiler must not be put into operation. If put into operation nonetheless, the burner will not be able to function properly, and explosions will occur when setting the flame and ultimately malfunctions; the burner will therefore fail and the heating system will shut down.