Measuring range | -58° to 302 °F / -50 to +150 °C |
---|---|
Accuracy | ±0.9 °F / ±0.5 °C |
Resolution | 0.1 °F / 0.1 °C |
Probe connection | 2 x plug-in (NTC) |
Measuring range | -15 to 870 psi / -1 to 60 bar |
---|---|
Accuracy | ±0.5 % Fs |
Resolution | 0.14 psi / 0.01 bar |
Probe connection | 3 x 7/16" – UNF |
Overload rel. (high pressure) | 943 psi / 65 bar |
Weight | 29.14 oz. / 826 g |
---|---|
Dimensions | 8.27 x 4.76 x 2.36 in. / 210 x 121 x 60 mm (LxWxH) |
Operating temperature | -4° to 122 °F / -20 to +50 °C |
Protection class | IP54 |
System requirements | requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0 |
Product colour | Black |
Auto-off | 10 min* |
Battery life | 250 h with no illumination, no Bluetooth<sup>®</sup>; 100 h with illumination and Bluetooth<sup>®</sup> |
Battery type | 4 x AA batteries |
Data transfer | Bluetooth® |
Radio range | 492.12 ft. / 150 m |
Refrigerants in instrument | R114; R12; R123; R1233zd; R1234yf; R1234ze; R124; R125; R13; R134a; R22; R23; R290; R32; R401A; R401B; R402A; R402B; R404A; R407A; R407C; R407F; R407H; R408A; R409A; R410A; R414B; R416A; R420A; R421A; R421B; R422B; R422C; R422D; R424A; R427A; R434A; R437A; R438A; R442A; R444B; R448A; R449A; R450A; R452A; R452B; R453a; R454A; R454B; R454C; R455A; R458A; R500; R502; R503; R507; R513A; R600a; R718 (H₂O); R744 (CO₂) |
Refrigerants update via App | R11; FX80; I12A; R1150; R1270; R13B1; R14; R142B; R152A; R161; R170; R227; R236fa; R245fa; R401C; R406A; R407B; R407D; R41; Ra11A; R412A; R413A; R417A; R417B; R417C; R422A; R426A; R508A; R508B; R600; RIS89; SP22 |
Refrigerant | A2L / A3 compatibel |
Storage temperature | -4° to 140 °F / -20 to +60 °C |
* when not connected via Bluetooth |
Measuring range | -40° to 302 °F / -40 to +150 °C |
---|---|
Accuracy | ±2.3 °F (-4° to 185 °F) / ±1.3 °C (-20 to +85 °C) |
Resolution | 0.1 °F / 0.1 °C |
Weight | 4.49 oz. / 127.4 g |
---|---|
Dimensions | 7 x 4 x 1 in. / 183 x 90 x 30 mm |
Operating temperature | -4° to 122 °F / -20 to +50 °C |
Housing | Plastic |
System requirements | requires iOS 11.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.0 |
Product colour | black/orange |
Battery type | 3 x AAA |
Battery life | 150 h |
Storage temperature | -4° to 140 °F / -20 to +60 °C |
Measuring range | 0 to 0.39 psi / / 0 to 26.66 mbar / 0 to 20000 micron |
---|---|
Accuracy | ±(1 ±10 micron + 10 % of mv (100 to 1000 micron) |
Resolution | 100 micron (2000 to 5000 micron) / 1 micron (0 to 1000 micron) / 10 micron (1000 to 2000 micron) / |
Overload | absolute: 87.0 psi / 87 psi / absolute: 6.0 bar / 87 psi (relative: 72.5 psi / 72 psi) / (relative: 5.0 bar / 72 psi) |
Weight | 5 oz. / 142 g |
---|---|
Dimensions | 6 x 1 x 1 in. (LxWxH) / 150 x 32 x 31 mm (LxWxH) |
Operating temperature | 14.0° to 122.0 °F / -10 to +50 °C |
Protection class | IP54 |
System requirements | requires iOS 12.0 or newer; requires Android 6.0 or newer; requires mobile end device with Bluetooth 4.2 |
Product colour | black/orange |
Auto-off | 10 min* |
Battery type | 3 x AAA |
Battery life | 39 h |
Connection | 7/16“ UNF |
Interface | Bluetooth® 4.2 |
Storage temperature | -4.0° to 122.0 °F / -20 to +50 °C |
* when not connected via Bluetooth |
System requirements | requires iOS 13.0 or newer; requires Android 8.0 or newer; requires mobile end device with Bluetooth 4.0 |
---|---|
Some manufacturers specify exactly what the absolute pressure must be for you to evacuate your air conditioning systems and how long this pressure must be maintained. Compliance with these specifications is simple and easy thanks to the flexible setting of the alarm threshold in the testo 552.
Some manufacturers specify the desired micron lower limit that must be achieved to evacuate their air conditioning systems and how long this pressure must be maintained. Compliance with these specifications is simple and easy thanks to the flexible setting of the alarm threshold in the testo 552.
The testo 552 Digital Vacuum Gauge is for the evacuation of heat pumps, air conditioning, and refrigeration systems. The innovative testo 552 utilizes a sensor that, unlike the competition, requires no cleaning and is not affected by contamination. Never worry about a dirty sensor causing false readings. Trust your testo 552 to always be accurate.