Weight | < 11 oz. / < 300 g |
---|---|
Reaction time | t90 < 5 sec |
Operating temperature | 23° to 113 °F / -5 to +45 °C |
Heat up time | 60 sec |
Battery type | 2 AAA batteries 1.5 V (LR03) |
Battery life | 4 h (LR03) |
Display type | 8 segment trend display |
Storage temperature | -4° to 122 °F / -20 to +50 °C |
Measuring range | 100 to 20000 ppm |
---|---|
Lower response threshold | 100 ppm |
1st alarm limit | 10000 ppm (20% LEL) |
Measuring range | 50 to 10000 ppm |
---|---|
Lower response threshold | 50 ppm |
1st alarm limit | 5000 ppm (20% LEL) |
Gas leak detector for easy checks on gas pipe connections, with visual bar display. The 317-2 shows gas concentration in a visual bar-style display. The unit’s sensor conducts a self-test after turning on and an audible alarm confirms the instrument is ready for use. If the alarm sounds and continues to increase in volume, potentially unsafe gas concentrations are being reached. A continuous alarm will sound when the threshold has been exceeded.