Measuring range | -40° to 302 °F / -40 to +150 °C |
---|---|
Accuracy | ±0.5 % of mv (Remaining Range) ±0.7 °F (167° to 211.8 °F) / ±0.4 °C (+75 to +99.9 °C) ±0.4 °F (-13° to 166.8 °F) / ±0.2 °C (-25 to +74.9 °C) ±0.7 °F (-40° to -13.2 °F) / ±0.4 °C (-40 to -25.1 °C) |
Resolution | 0.1 °F / 0.1 °C |
Measuring range | -328.0° to 2498 °F / -200 to +1370 °C |
---|---|
Accuracy | ±0.5 °F (-76° to 140 °F) / ±0.3 °C (-60 to +60 °C) ±(0.4 °F + 0.5 % of mv) (Remaining Range) / ±(0.2 °C + 0.5 % of mv) (Remaining Range) |
Resolution | 0.1 °F / 0.1 °C |
Measuring range | 0 to +100 %rH |
---|---|
Accuracy | See probe data |
Resolution | 0.1 %rH |
Damp ceilings and walls may be a result of structural damage. In most cases, however, it is a sign of improper ventilation. Once the mould appears inside a house, the tenant assumes that moisture has come in from outside. Numerous disputes have erupted because of the issue of who is liable for the mould damage. However, it is difficult to find out who or what has caused the mould: the tenant or faulty structural design?
Testo 635-1 is ideal for measuring moisture in ceilings and walls. Using the optional attachment temperature/moisture probe and optional surface temperature probe, the testo 635 automatically calculates the dew point distance. It provides initial information about whether mould is being caused by condensation, or from moisture ingress due to structural damage or faulty insulation.
Our temperature/humidity measuring instruments are used around the world in production, storage and server rooms, museums, archives, cold storage warehouses, containers and sales counters.
Manufacturers, carriers, or dealers of sensitive products must ensure that specified temperature or humidity values are observed during production and storage. The testo 635 offers the option of performing spot measurements in relevant places.
The temperature/humidity measuring instrument testo 635-2 offers the user a wide range of humidity/moisture probes. It provides the option of measuring humidity, material moisture and U-value (for the thermal assessment of structural components). In addition to the standard probes, up to three radio probes can be connected to the device in parallel. Measurement results can be analysed, stored and documented using the supplied PC software.